Services

  • Air and Water Balancing  
  • Ultrasonic Flow Measurement Readings
  • Sound and Vibration Testing
  • Indoor Air Quality Testing
  • Building Systems Commissioning
  • Smoke Evacuation System Testing
  • Pre Demo Readings
  • Acceptance Testing
  • Fume Hood Testing
  • Coil Load Performance Testing
  • Duct Air Leakage Testing
  • Existing Building Surveys
  • Mechanical Inspections with Report and Recommendations
  • Temperature Trending
  • Digital Photos and or Video Reports of Fog Machine Air Flow Visualization
  • Air Exchange Rates / Pressure Relationship Certification
  • Stair Pressurization Testing
  • Fire Life Safety


Striving towards customer satisfaction

How can we help?

AIR SYSTEM TEST PROCEDURES 

​Air system testing and reporting shall be performed in accordance with instrumentation and procedures as defined within the 2005 NEBB 

Procedural Standards for Testing, Adjusting and Balancing of Environmental Systems. ​ ​


Instrumentation ​

All air system testing and balancing shall be performed with instrumentation in compliance with guidelines identified within the NEBB procedural standards. Selection of specific instrumentation for each application will be made to secure maximum accuracy level of test data. Listing of specific instrumentation and calibration records shall be submitted with final test report. ​ 

Sample Test Report Format if Requested  


WATER SYSTEM TEST PROCEDURES ​

Water system testing and reporting shall be performed in accordance with instrumentation and procedures as defined within the 2005 NEBB ​

Procedural Standards for Testing, Adjusting and Balancing of Environmental Systems.  ​


Instrumentation​

All water system testing and balancing shall be performed with instrumentation in compliance with guidelines identified within the NEBB procedural standards. Selection of specific instrumentation for each application will be made to secure maximum accuracy level of test data. Listing of specific instrumentation and calibration records shall be submitted with final test report. ​Sample Test Report Format if Requested 

TESTING AND BALANCING

Instrumentation ​

The following is a listing of proposed instrumentation used for data acquisition. Sample formats and test instrumentation submitted shall comply with data acquisition and reporting requirements set forth within the current NEBB 

Procedural Standards for Testing, Adjusting and Balancing of Environmental Systems. ​ ​ 


Calibration histories of actual instrumentation used will be provided with final test report. Instruments utilized comply with identified range and accuracy requirements.

SOUND TEST PROCEDURES 

Sound testing and reporting shall be performed in accordance with instrumentation and procedures as defined within the 2006 NEBB ​

Procedural Standards for the Measurement and Assessment of Sound & Vibration. 

 

Instrumentation

All sound tests will be performed with a CESVA Model Precision Sound Level Meter and Octave Ban Analyzer. This instrument conforms to ANS1 S1.4 Type 1 and 1EC 179 and is ideal for ASHA compliance measurements. We carry a CESVA CB-5 Calibrator with the instrument at all times and meter calibration is verified before performing sound level testing.  


Timing

Sound level measurements will be performed when the space is relatively quiet with a minimum of activity and background noise.  


Specific Test Procedures 

The microphone will be positioned no closer than three feet from any floor, wall or ceiling, or no closer than six feet from any terminal or room unit. Sound pressure levels will be tested as prescribed in project specifications. ​ 


Reports

1. The following data shall be included on final report: 

2. Measurements at the specified frequencies with the tested equipment turned on. 

3. Measurements at the specified frequencies with the tested equipment turned off. 

4. Corrective calculation, if required, between equipment noise and ambient noise levels. 

5. The "Equipment Components" of the room sound level.Graphical representation of   equipment component, if required. 

6. ​Identification of test location. ​  


BUILDING SYSTEMS COMMISSIONING 

​All procedures and reporting shall be performed in accordance with procedures as defined within the NEBB 2009 

Procedural Standards for Building Systems Commissioning of Environmental Systems, and Project Specifications.

The above instrumentation key is provided for reference.

The above instrumentation key is provided for reference.

NEBB Pre-TAB Checklist (pdf)

Download

Test Reports Sample Sheet (pdf)

Download

Copyright © 2022 Comfort Control Balance - All Rights Reserved.

Main Office 6711 Distribution Drive, Beltsville, Maryland 20705    Phone: 301-931-9300 ♦ Fax: 301-931-0369

NC Branch Office 2228 Page Road Ste. 101, Durham, North Carolina 27703     Phone: 919-381-5065 ♦ Fax: 919-381-5095

  • Welcome
  • About Us
  • History
  • Supervisors
  • Technicians
  • Services
  • Projects
  • Contact Us

This website uses cookies.

We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.

Accept